IBM H80 Instrukcja Użytkownika Strona 145

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 230
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 144
Download Microcode to Disk Drive Attached to a PCI SCSI RAID
Adapter
See the following command syntax for a disk drive attached to a PCI SCSI RAID
Adapter.
diag -c -d
RAID adapterName
-T "download {-l
chID
| -A} [-D] [-P]"
Flag Description
-A All disk drives
-D Microcode is on diskette (default to /etc/microcode directory)
-l RAID disk drive–physical disk channel/ID (example 27)
-P Download the previous level of microcode (default to latest level)
Download Microcode to a PCI FC-AL Adapter
See the following command syntax for a PCI FC-AL Adapter.
diag -c -d
device_name
-T "download [-s {diskette|disk}]
[-f] [-l {latest|previous}]"
Flag Description
-d Device name is the name of the adapter.
-f Force the download even if the current level of microcode is not on the
media.
-l Level of microcode to download. The default is latest.
-s Source of the new microcode. The default value is disk.
The microcode image file must be located in /etc/microcode.
Download Microcode to Other Devices
The following usage statements describe the syntax of the command:
diag -c -d
device_name
-T "download [-s diskette] [-l previous] [-F]"
Flag Description
-F Force flag. Required to download microcode if the current level is
unavailable on the source.
-l Microcode level. Latest is default.
-s Source of the new microcode. The default is /etc/microcode. Default
source device is disk.
Chapter 6. Introducing Tasks and Service Aids 129
Przeglądanie stron 144
1 2 ... 140 141 142 143 144 145 146 147 148 149 150 ... 229 230

Komentarze do niniejszej Instrukcji

Brak uwag