Podsumowanie treści

Strona 1 - ERserver

xSeries 445 Type 8870User’s Guide ERserver 

Strona 2

Statement 4: ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb) CAUTION: Use safe practices when lifting. Statement 5: CAUTION: Th

Strona 3 - ER s e r v e r

Statement 8: CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, an

Strona 4

WARNING: Handling the cord on this product or cords associated with accessories sold with this product, will expose you to lead, a chemical known to t

Strona 5 - Contents

Chapter 1. Introducing the IBM xSeries 445 server Your IBM®ERserver™xSeries® 445 server is a 4-U-high1 rack model server for high-volume network trans

Strona 6

v Hardware Maintenance Manual and Troubleshooting Guide This document is in PDF on the IBM xSeries Documentation CD. It contains information to help

Strona 7 - Copyright

Features and specifications The following information is a summary of the features and specifications of your server. Microprocessor: v Supports th

Strona 8

What your server offers Your server uses the following features and technologies: v IBM Director IBM Director is a workgroup-hardware-management too

Strona 9

v Large data-storage capacity and hot-swap capability Your server supports up to two 25.4-mm (1-inch) slim-high, 3.5-inch hot-swap hard disk drives

Strona 10

Reliability, availability, and serviceability features Three important computer design features are reliability, availability, and serviceability (RAS

Strona 11

Active Memory Active Memory is an IBM feature that improves the reliability of memory through memory mirroring, memory scrubbing, and the Memory Prote

Strona 13

IBM Director With IBM Director, a network administrator can: v View the hardware configuration of remote systems, in detail v Monitor the usage an

Strona 14

Server controls, LEDs, and power The following section identifies the controls and indicators on the front and rear of your server. Front view AC an

Strona 15 - Features

SCSI activity LED: This green LED is lit when there is activity on the SCSI bus. Locator LED: The locator LED is on the left front of the Light Path D

Strona 16

Rear view System power connectors (1 and 2): Connect the system power cords to these two connectors to provide power to the system. RXE Expansion P

Strona 17

Remote Supervisor Adapter II-EXA connectors and LEDs: This group of connectors and LEDs on the back of the server is used for system-management inform

Strona 18 - Reliability

v External power connector: You can connect an optional ac power adapter to this connector. v Error LED: This amber LED is lit when a system-manag

Strona 19

SMP Expansion port 1: Use this port to interconnect two SMP Expansion Modules together. Server power features When the server is connected to an ac po

Strona 20 - Director

Turning off the server When you turn off the server and leave it connected to ac power, the server can respond to requests from the service processor,

Strona 21

16 xSeries 445 Type 8870: User’s Guide

Strona 22

Chapter 2. Configuring the server The following configuration programs and capabilities come with your server: v Configuration/Setup Utility program

Strona 23

xSeries 445 Type 8870User’s Guide ER s e r v e r 

Strona 24

v Preboot Execution Environment (PXE) boot agent utility program The PXE boot agent utility program is part of the BIOS code in your server. Use it

Strona 25

v System Information Select this choice to view information about your server. When you make changes through other options in the Configuration/Setu

Strona 26

– Administrator Password Attention: If you set an administrator password and then forget it, there is no way to change, override, or remove it. Yo

Strona 27

The following information applies to memory mirroring: - The hot-add memory feature allows you to add DIMMs without turning off the server. This fea

Strona 28

– System Error Log Select this choice to view the System Error log, which contains all system error and warning messages that have been generated. U

Strona 29 - Configuring

1. If you have not already done so, connect the RXE expansion and RXE management cables between the server and the remote expansion enclosure. See ″

Strona 30

9. Save and Exit the Configuration/Setup Utility Program. Note: See the software documentation that comes with your operating system to install your

Strona 31

Passwords From the System Security choice, you can set, change, and delete a power-on password and an administrator password. The System Security choi

Strona 32

While the server is turned off, move the switch to the position opposite its current position. You can then start the Configuration/Setup Utility prog

Strona 33

Using the ServerGuide Setup and Installation CD The ServerGuide Setup and Installation CD includes an easy-to-use setup and installation program that

Strona 34

Note: Before using this information and the product it supports, read the general information in Appendix A, “Getting help and technical assistance,”

Strona 35

Setup and configuration overview When you use the ServerGuide Setup and Installation CD, you do not need setup diskettes. You can use the CD to config

Strona 36 - Deleting

The following table contains information about the supported operating systems. Note: All listed operating systems are supported by the Remote Supervi

Strona 37 - Passwords

Configuring the Gigabit Ethernet controller The Ethernet controller is integrated on the system board. It provides an interface for connecting to a 10

Strona 38 - Administrator

Complete the following steps to start the LSI Logic Configuration Utility program: 1. Turn on the server. 2. When the prompt <<< Press &l

Strona 39

Configuring the controller By running ServeRAID Manager in Startable CD mode, you can configure the controller before you install your operating syste

Strona 40

Using express configuration Complete the following steps to use express configuration: 1. In the ServeRAID Manager tree, click the controller. 2.

Strona 41

Using custom configuration Complete the following steps to use custom configuration: 1. In the ServeRAID Manager tree, click the controller. 2.

Strona 42

8. Review the information in the “Configuration summary” window. To change the configuration, click Back. 9. Click Apply; then, click Yes when as

Strona 43 - ServeRAID

Viewing the configuration You can use ServeRAID Manager to view information about RAID controllers and the RAID subsystem (such as arrays, logical dri

Strona 44

Getting assistance For more information about ServeRAID Manager, see the online help system. To start the help system, click Help on the toolbar or se

Strona 45 - “Configuration

Contents Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .v Chapter 1. Introducing the IBM xSeries 445 server . . . . . . . . . . .1 Re

Strona 46

The help system (ServeRAID Assist) will open within the ServeRAID Manager interface. To learn more about the ServeRAID Manager tree objects and the

Strona 47

Remote Supervisor Adapters This section describes how to identify the Remote Supervisor Adapter by its features and prerequisites for setup. It also e

Strona 48

Setting up the Remote Supervisor Adapter II-EXA This section describes features, setup requirements, and how to cable and configure the Remote Supervi

Strona 49

v The remote disk function requires the following software: – Server (for the server operating system to support the remote disk): Microsoft Windo

Strona 50

The RSA II-EXA breakout cable: The ASM breakout cable connects the Remote Supervisor Adapter II-EXA to the ASM interconnect network, the server USB

Strona 51

Cable the Remote Supervisor Adapter II-EXA: This section provides the information needed to cable the Remote Supervisor Adapter II. 1. Connect the

Strona 52

b. Check the Remote Supervisor Adapter II-EXA Ethernet link and activity LEDs. The location of the LEDs are shown in the following illustration. v

Strona 53

For Microsoft Windows 2000 or Windows Server 2003: If the server in which the Remote Supervisor Adapter II-EXA is installed is running the Microsoft

Strona 54 - Management

v IBM Eserver xSeries BIOS update with support for the Remote Supervisor Adapter II-EXA v Diagnostics code update v Remote Supervisor Adapter II

Strona 55

v Controlling the server remotely v Virtually attaching a remote diskette drive, CD-ROM drive, or disk image to the server If you want to set up a

Strona 56

Edition notice . . . . . . . . . . . . . . . . . . . . . . . . .73 Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . .74 Important notes

Strona 57

An ASM interconnect network can have up to 24 RS-485 connections, depending on the configuration. The connections can include Remote Supervisor Adapte

Strona 58

resources, enabling Remote Supervisor Adapters, ASM processors, ASM PCI adapters, and ISMPs on the ASM interconnect network to send alerts using a mod

Strona 59

ASM interconnect network configuration examples: The illustrations in this section show sample ASM interconnect network configurations. In the follo

Strona 60

In the following example, a Remote Supervisor Adapter II-EXA is installed in an xSeries 44, and creates an interconnect network with the other xSeries

Strona 61

Setting up the Remote Supervisor Adapter This section describes features, setup requirements, and how to cable and configure the Remote Supervisor Ada

Strona 62 - Remote system

v To configure the remote alert recipients for Director over LAN or Director over modem, the remote alert recipient must be an IBM Director-enabled

Strona 63

Cabling the Ethernet LAN port and management port: This section describes how to cable the Remote Supervisor Adapter. You can manage the server remo

Strona 64

2. Check the Ethernet LEDs to ensure that the network connection is working. The following illustration shows the location of the LEDs. v Externa

Strona 65

Note: For detailed information about using the ASM Web interface and the text-based user interface, see the Remote Supervisor Adapter User’s Guide on

Strona 66

3. Use the arrow keys to select Ethernet Settings; then, press Enter. The Ethernet Settings window opens, as shown in the following illustration. No

Strona 67

Safety Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Segurança. Pred

Strona 68

10. Use the arrow keys to select Exit Utility from the menu or press Esc to close the Utility program. 11. Remove the diskette from the server. Th

Strona 69

You can dedicate the integrated management port on the Remote Supervisor Adapter to system management or share it with the operating system. If the ma

Strona 70

The PPP Settings window opens, as shown in the following illustration. Note: The values in the window are only examples; your settings might be differ

Strona 71

7. Press Esc to return to the Configuration Settings window. If you need to configure the management port, go to “Configuring the management port fo

Strona 72

3. If you are installing from a CD, type: d:\DD\WIN2000\SETUP, where d is the drive letter of the DVD-ROM drive. 4. Follow the directions that dis

Strona 73

Configuring the remote control password: If you want to use the remote control features of the Remote Supervisor Adapter ASM Web interface, you must

Strona 74

where other Remote Supervisor Adapters, ASM processors, and ASM PCI Adapters on the network reside. Second, the ASM interconnect network enables other

Strona 75

communications resources are available for use by other servers on the ASM interconnect network. These resources are then used as ASM interconnect net

Strona 76

Server name ASM Interconnect module needed xSeries 220 yes xSeries 232 yes xSeries 240 yes xSeries 330 The ASM interconnect module is required to link

Strona 77

2. Connect one or two Category 3 or Category 5 Ethernet cables to the other end of the ASM Interconnect module. 3. Continue with “ASM interconnect

Strona 78

Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. Statement 1:

Strona 79

ASM interconnect network configuration examples: The illustrations in this section show sample ASM interconnect network configurations. The followin

Strona 80

The following illustration shows a modem connected to the management port of the Remote Supervisor Adapter in the xSeries 445 server on the left, a mo

Strona 81

Using the PXE boot agent utility program Use the Preboot Execution Environment (PXE) boot agent utility program to enable or disable operating-system

Strona 82

Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about IBM products,

Strona 83

Getting help and information from the World Wide Web On the World Wide Web, the IBM Web site has up-to-date information about IBM xSeries and IntelliS

Strona 84

Appendix B. Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or featur

Strona 85 - Appendix

Trademarks The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both: Active M

Strona 86 - Trademarks

Important notes Processor speeds indicate the internal clock speed of the microprocessor; other factors also affect application performance. CD-ROM dr

Strona 87

Battery return program This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery. Consult you

Strona 88

Industry Canada Class A emission compliance statement This Class A digital apparatus complies with Canadian ICES-003. Avis de conformité à la réglemen

Strona 89

Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufac

Strona 90

Chinese Class A warning statement Japanese Voluntary Control Council for Interference (VCCI) statement Power cords For your safety, IBM provides

Strona 91

IBM power cords for a specific country or region are usually available only in that country or region. IBM power cord part number Used in these count

Strona 92

IBM power cord part number Used in these countries and regions 6952300 Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Caicos

Strona 93

Index Aacoustical noise emissions 3 Active Memory 4, 7 administrator password 25 alerts, forwarding 48, 64 ASM interconnect network 63 cabling 65 comp

Strona 94

light path diagnostics 5 LOC (location) LED 10 local area network (LAN) 4 LSILogic Configuration Utility program 17 Mmanagement port, cabling 55 memor

Strona 95

starting (continued)server 14 statements and notices 2 symmetric multiprocessing 5 systems management 5, 8 Ttechnical assistance, getting 71 telnet 59

Strona 96

84 xSeries 445 Type 8870: User’s Guide

Strona 98

Part Number: 02R2784 Printed in USA (1P) P/N: 02R2784